pdf-logo_002
View & Download PDF

Pressure transmitters for industrial applications

Type MBS 4510


Features

  • Designed for use in severe industrial environments
  • Enslosure and wetted parts of acid-resistant stainless steel (AISI 316L)
  • Pressure ranges in relative (gauge) or absolute up to 25 bar
  • Output signal: 4 – 20 mA
  • Temperature compensated and laser calibrated
  • Accuracy 0,5% FS
  • Zero and span adjustment
  • USDA-H1 approved oil filling

MBS_4510_001Description
The high accuracy flush diaphragm pressure transmitter  MBS 4510 is designed  for use in non-uniform, high viscous or crystallizing media within industrial applications, and offers a reliable pressure measurement, even under harsh envi- ronmental conditions. The flexible pressure transmitter  programme covers a 4-20 mA output signal, absolute and gauge (relative) versions, measuring ranges from 0-0.25 to 0-25 bar zero and span adjustment. A rotatable plug connection and a G1A conic pres- sure connection with flush mounted diaphragm. Excellent vibration stability, robust construction, and a high degree of EMC/EMI protection equip the pressure transmitter  to meet the most stringent industrial requirements.

Ordering
standard versions
Plug: Pg 9 (EN 175301-803-A)
Output: 4-20 mA
Pressure connection: G 1 A with cone

Measuring range Pe 1)[bar] Max. operating pressure[bar] Min. burst pressure [bar] Code. no
0 -0.25 2 50 060G2418
0 – 0.4 2 50 060G2419
0 – 0.6 2 50 060G2420
0 – 1 2 50 060G2421
0 – 1.6 8 50 060G2422
0 -2.5 8 50 060G2423
0 – 4 8 50 060G2424
0 – 6 20 50 060G2425
0 – 10 20 50 060G2426
0 – 16 50 100 060G2427
0 – 25 50 100 060G2428
Performance (EN 60770)
Accuracy (incl. non-linearity, hysteresis and repeatability) ±0.2% FS (typ.)
±0.5% FS (max.)
Non-linearity BFSL (conformity) ≤ ±0.2% FS
Hysteresis and repeatability ≤ ±0.1% FS
Thermal zero point shift Measuring range: 0-250 mbar ≤ ±0.4% FS/10K
Measuring range: 0-400 mbar ≤ ±0.3% FS/10K
Measuring range: ≥0-600 mbar ≤ ±0.2% FS/10K
Thermal sensitivity (span) shift Measuring range: 0-250 mbar ≤ ±0.4% FS/10K
Measuring range: 0-400 mbar ≤ ±0.35% FS/10K
Measuring range: ≥0-600 mbar ≤ ±0.2% FS/10K
Response time < 4 ms
Max. operating pressure See page 2
Burst pressure Pe versions See page 2
Pabs versions Min. 300 bar
Durability, P: 10-90% FS >10×10 cycles
Zero point adjustment 0-0.25 to 0-10 bar mearsuring range -5 to +20 % FS
0-16 to 0-25 bar measuring range -5 to +10% FS
Span adjustment 0-0.25 to 0-25 bar measuring range -5 to +5% FS
Electrical specifications
Nom. output signal (short curcuit protected) 4 to 20 mA
Supply voltage, UB (polarity protected) 10 to 30 V d.c.
Supply voltage dependency ≤ ±0.05% FS/10 V
Current limitation (linear output signal up to 1.5 × rated range) 28 mA (typ.)
Load [RL] (load connected to 0 V) CODE NEEDED
Environmental conditions
Media temperature range −10 → +85 °C
Ambient temperature range −10 → + 85 °C
Compensated temperature range 0 → +80°C
Transport temperature range −25 → +85°C
EMC – Emission EN 61000-6-3
EMC Immunity EN 61000-6-2
Insulation resistance > 100 MΩ at 100 V
Mains frequency test SEN 361503
Vibration stability Sinusoidal 15.9 mm-pp, 5 Hz-25 Hz 20 g, 25 Hz – 2 kHz Random 7.5 grms,5 Hz – 1 kHz IEC 60068-2-6 IEC 60068-2-64
Shock resistance Shock Free fall 500 g / 1 ms IEC 60068 – 2 – 27 IEC 60068 – 2 – 32
Enclosure (IP protection fulfilled together with mating connector) IP65
Mechanical characteristics
Materials Wetted parts EN 10088-1; 1.4404 (AISI 316 L)
Enclosure EN 10088-1; 1.4404 (AISI 316 L)
Electrical connections Glass filled polyamid, PA 6.6
Gasket (above thread) DIN 3869-33-NBR
Weight 0.4 kg

Electrical connections

Graph_4510_001

Dimensions

Graph_4510_002

Installation

Graph_4510_003

Adjustment

Graph_4510_004

Accessories

Graph_4510_005