VLT® Micro Drive
The compact general purpose drive
The VLT® Micro Drive is a general purpose drive that can control AC motors up to 22 kW. It’s a small drive with maximum strength and reliability.
RoHS compliant
The VLT® Micro Drive is manufactured with respect for the environment, and it complies with the RoHS Directive.
The perfect match for:
• Industrial appliances
• HVAC applications
• OEM
Power range:
1 phase 200–240 V AC: 0.18–2.2 kW
3 phase 200–240 V AC: 0.25–3.7 kW
3 phase 380–480 V AC: 0.37–22 kW
| Features | Benefits |
|---|---|
| User friendly | |
| . Minimum commissioning | . Saves time |
| . Mount-connect-go! | . Minimum effort-minimum time |
| . Copy setting via local control panel | . Easy programming of multiple drives |
| . Intuitive parameter structure | . Minimal manual reading |
| . Complies with VLT* software | . Saves commissioning time |
| Self-protecting features | . Lean operation |
| . Process PI-controller | . No need for external controller |
| . Automatic Motor Adatation (AMA) | . Exploits motor’s full potential |
| . 150% motor torque up to 1 minute | . Plenty of brake-away and acceleration torque |
| . Flying start (catch a spinning motor) | . Doesn’t trip when started on a spinning (freewheeling) motor |
| . Electronic Thermal Relay (ETR) | . Replaces external motor protection |
| . Precise stop function | . Lean production – more up-time |
| . Smart Logic Controller | . Often makes PLC unnecessary |
| . Built-in RFI filter | . Saves cost and space |
| Energy saving | Less operation |
| . Energy efficiency 98% | . Minimises heat loss |
| . Automatic Energy Optimisation (AEO) | . Saves 5-15% energy in HVAC applications |
| Reliable | Maximum uptime |
| . Earth fault protection | . Protects the drive |
| . Over temperature protection | . Protects the motor and drive |
| . Short circuit protection | . Protects the drive |
| . Optimum heat dissipation | . Longer lifetime |
| . High quality electronics | . Low lifetime cost |
| . High quality capacitors | . Tolerates uneven mains supply |
| . All drives full load tested from factory | . High reliability |
| . Dust resistant | . Optimised productivity |
| . Tight enclosure | . Increased lifetime |
| . RoHS compliant | . Protects the environment |
| . Designed for WEEE | . Protects the environment |
Coated PCB standard For harsh environments.
Power options
Danfoss Drives offers a range of external power options for use together with our drives in critical networks or applications.
PC software
• MCT 10
– Ideal for commissioning and servicing the drive including guided programming of cascade controller, real-time clock, smart logic controller and preventive maintenance.
• VLT® Energy Box
– Comprehensive energy analysis tool, shows the drive payback time.
• MCT 31
– Harmonics calculations tool.
| Specifications | |
|---|---|
| Mains supply (L1, L2, L3) | |
| Supply voltage | 1×200-240V +/-10%, 3×200-240V +/-10% 3×380-480V +/- |
| Supply frequency | 50/60 Hz |
| Displacement Power Factor (cos ) near unity | (0.98) |
| Switching on input supply L1, L2, L3 | 1-2 times/min. |
| Output data (U, V, W) | |
| Output voltage | 0-100% of supply voltage |
| Output frequency | 0-200 Hz (VVC+mode), 0-400 Hz (U/f mode) |
| Switching on output | Unlimited |
| Ramp times | 0.05-3600 sec |
| Digital inputs | |
| Programmable inputs | 5 |
| Logic | PNP or NPN |
| Voltage level | 0-24V |
| Pulse inputs | |
| Programmable pulse inputs | 1* |
| Voltage level | 0-24V DC (PNP positive logic) |
| Pulse input frequency | 20-5000 Hz |
| *One of the digital inputs can be used for pulse inputs. | |
| Analog inputs | |
| Analog inputs | 2 |
| Modes | 1 current/1 voltage or current |
| Voltage level | 0-10V (scaleable) |
| Current level | 0/4-20mA (scaleable) |
| Analog output | |
| Programmable analog output | 1 |
| Current range at analog output | 0/4-20mA |
| Relay outputs | |
| Programmable relay outputs | 1 (240 VAC, 2A) |
| Approvals | |
| CE, C-tick, UL | |
| Fieldbus communication | |
| FC Protocol, Modbus RTU |
| ORDERING NUMBERS | |||||
|---|---|---|---|---|---|
| 200V | 400V | ||||
| Power [kW] | Current [I-nom.] | 1 ph. | 3 ph. | Current [I-nom.] | |
| 0.18 | 1.2 | 132F 0001 | |||
| 0.25 | 1.5 | 132F 0008 | |||
| 0.37 | 2.2 | 132F 0002 | 132F 0009 | 1.2 | 132F 0017 |
| 0.75 | 4.2 | 132F 0003 | 132F 0010 | 2.2 | 132F 0018 |
| 1.5 | 6.8 | 132F 0005 | 132F 0012 | 3.7 | 132F 0020 |
| 2.2 | 9.6 | 132F 0007 | 132F 0014 | 5.3 | 132F 0022 |
| 3.0 | 7.2 | 132F 0024 | |||
| 3.7 | 15.2 | 132F 0016 | |||
| 4.0 | 9.0 | 132F 0026 | |||
| 5.5 | 12.0 | 132F 0028 | |||
| 7.5 | 15.5 | 132F 0030 | |||
| 11.0 | 23.0 | 132F 0058 | |||
| 15.0 | 31.0 | 132F 0059 | |||
| 18.5 | 37.0 | 132F 0060 | |||
| 22.0 | 43.0 | 132F 0061 |
VLT* Control Panel LCP 11 – Without Potentiometer 132B0100
VLT* Control Panel LCP 12 – Without Potentiometer 132B0101
| CABINET SIZES | |||||
|---|---|---|---|---|---|
| (mounting flange included) | |||||
| [mm] | M1 | M2 | M3 | M4 | M5 |
| Height | 150 | 176 | 239 | 292 | 335 |
| Width | 70 | 75 | 90 | 125 | 165 |
| Depth | 148 | 168 | 194 | 241 | 248 |
- 6mm with Potentiometer