Pressure transmitter for air and water applications

Type MBS 1900

The pressure transmitter  MBS 1900 is designed for use in air and water applications like Booster Pumps and Air Compressors. The semi-flexible pressure transmitter  programme covers different output signals, absolute or gauge (relative) versions, measuring ranges from 0 – 4 bar to 0 – 25 bar and a wide range of pressure and electrical connections. Enclosure material is stainless steel AISI 316L.

MBS1900_004Features
y  Designed for use in air and water applications
y  Wetted parts of stainless steel (AISI 304)
y  Pressure ranges in relative (gauge) or absolute from 0 up to 25 bar
y  Output signals: 4 – 20 mA, or ratio metric
y  Absolute or relative (gauge) sensor element
y  A wide range of pressure and electrical connections
y  Digitally compensated

Approvals

UL Approval,  Certificate number: E31024

 

Performance (EN 60770)
Accuracy (@ 20 °C) (incl. non-linearity, hysteresis and repeatability) ≤ ± 1.0% FS
Non-linearity BFSL (conformity) ≤ ± 0.5% FS
Hysteresis and repeatability ≤ ± 0.1% FS
Total error band inside the compensated temperature range ≤ ± 3.0% FS
Response time < 4 ms
Overload pressure (Static) 3 × FS (max. 75 bar)
Burst pressure 4 × FS (max. 100 bar)
Durability, P: 10 – 90% FS > 10 ×106 cycles
Electrical specifications
Nom. output signal (short-circuit protected) 4 − 20 mA Ratiometric (10 – 90% of Vsupp.)
Supply voltage [UB], polarity protected 9 – 28 V 5 V ± 10%
Supply – current consumption ≤ 5 mA
Supply voltage dependency ≤ ± 0.1% FS / 10 V ≤ ± 0.1% FS / 10 V
Load [RL] (load connected to 0V ) RL ≤ (UB -10V ) / 0.02A RL ≥ 5 KΩ @ 5 V d.c.
Output impedance < 25 Ω
Environmental conditions
Sensor temperature range 0 – 80 °C
Max. media temperature 110 – (0.35 × ambient temperature)
Ambient temperature range (depending on electrical connection) -20 – 80 °C
Compensated temperature range 0 – 80 °C
Transport / Storage temperature range -50 – 85 °C
EMC – Emission EN 61000-6-3
EMC – Immunity EN 61000-6-2
Insulation resistance > 100 MΩ at 500 V
Vibration stability Sinusoidal 15 g, 5 Hz – 2 kHz IEC 60068-2-6
Random 7.5 g rms , 5 Hz – 1 kHz IEC 60068-2-64
Shock resistance Shock 200 g / 1 ms IEC 60068-2-27
Free fall 1 m IEC 60068-2-32
Enclosure (depending on electrical connection) see page 4
Mechanical characteristics
Materials Wetted parts EN 10088-1; 1.4301 (AISI 304)
Enclosure EN 10088-1; 1.4404 (AISI 316 L)
Electrical connections see page 4
Net weight (depending on pressure connection and electrical connection) 0.15 – 0.3 kg
Mounting instructions
Width across flats 24 mm
Mounting torque max 20 Nm

Ordering standard

Non-standard build-up combinations may be selected. However, minimum order quantities may apply. Please contact your local Danfoss office for further information or request on other versions.

MBS1900_001

Dimensions / Combinations

MBS1900_002

MBS1900_003