VLT Soft Starter MCD 500

VLT® Soft Starter MCD 500 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles.

AAC, Adaptive Acceleration Control, automatically employs the best starting and stopping profile for the application.

500_001Adaptive Acceleration Control means that for each start and stop, the soft starter compares and adapts the process to the chosen profile fitting to the application.
VLT® Soft Starter MCD 500 has a four line graphical display and a logic

keypad making programming easy. Advanced setup is possible displaying operational status.

Three menu systems: Quick Menu, Application Setup and Main Menu provide optimum programming approach.

Power range:
21 – 1600 A, 7.5 – 850 kW
(1.2 MW inside Delta Connection) Versions for 200 – 690 VAC

Features Benefits
AAC Adaptive Acceleration Control – Automatically adapts to the chosen starting and stopping profile
Adjustable bus bars allow for both top and bottom entry (360–1600 A, 160–850 kW) – Space saving, less cable cost and easy retrofitting
DC injection braking distributed evenly over three phases – Less installation cost and less stress on the motor
Inside Delta (6-wire connection) – Smaller soft starter can be selected for the application
Log menus, 99 events and trip log provide information on events, trips and performance – Eases analysis of the application
Auto Reset – Less down-time
Jog (slow-speed operation) – Application flexibility
Second-order thermal model – Allows motors to be used to their full potential without damage from overloading
Internal bypass contractors(21-215 A 7.5-110LW) – Saves space and wiring compared to external bypass. Very little heat dissipates when running. Eliminates costly external fans, wiring or bypass contractors
Auto-start/stop clock – Application flexibility
Compact size-amoungst the smallest in their class – Saves space in cabinets and other application setups
4-line graphical display – Optimum programming approach and setup for viewing operational status
Multiple programming setup (Standard Menu, Extended Menu, Quick Set) – Simplifies the programming but still holding to maximum flexibility
Multiple languages – Serving the whole world

Fully featured Soft Starter for motors up to 850 kW

  • Total motor starting solution
  • Advanced start, stop and protection features
  • Adaptive Acceleration Control
  • Inside Delta connection
  • 4-line graphical display
  • Multiple programming setup menus

Optional:

Modules for serial communication:

  • DeviceNet
  • Profibus
  • Modbus RTU
  • USB
  • Control Panel VLT® LCP  501

PC software:

  • WinMaster
  • WinStart
  • VLT® MCT10
Specifications
Mains voltage (L1, L2, L3)
MCD5-xxxx-T5 380 VAC ~ 690 VAC (± 10%) (in-line connection)
MCD5-xxxx-T7 – Less installation cost and less stress on the motor
MCD5-xxxx-T7 380 VAC ~ 600 VAC (± 10%) (inside delta connection)
Control voltage (terminals A4, A5, A6)
CV1 (A5, A6) 24 VAC/VDC (± 20%)
CV2 (A5, A6) 110~120 VAC (+ 10% / – 15%)
CV2 (A4, A6) 220~240 VAC (+ 10% / – 15%)
Mains frequency 50/60 Hz (± 10%)
Rated insulation voltage to earth 600 VAC
Rated impulse withstand voltage 4 kV
Form designation Bypassed or continuous, semiconductor motor starter form 1
Short circuit capability
Coordination with semiconductor fuses Type 2
Coordination with HRC fuses Type 1
MCD500-0021B to 0215B Prospective current of 65 kA
MCD500-0245C Prospective current of 85 kA
MCD500-1200C to 1600C Prospective current of 100 kA
. Password protection . Reliable operation
Electromagnetic capability (compliant with EU Directive 89/336/EEC)
EMC Emissions (Terminals 13 & 14) IEC 60947-4-2 Class B and Lloyds Marine No. 1 Specification
EMC Immunity IEC 60947-4-2
Outputs
Relay Outputs 10A @ 250 VAC resistive, 5A @ 250 VAC AC15 pf 0.3
Programmable Outputs
Relay A (13, 14) Normally open
Relay B (21, 22, 24) Changeover
Relay C (33, 34) Normally open
Analogue Output (07, 08) 0 – 20 mA or 4 – 20 mA (selectable)
Maximum load 600 Ω (12 VDC @ 20 mA) (accuracy ± 5%)
24 VDC Output (16, 08) Maximum load 200 mA (accuracy ± 10%)
Environmental
Protection MCD5-0021B ~ MCD5-0105B IP 20 & NEMA, UL Indoor Type 1
Protection MCD5-0131B ~ MCD5-1600C IP 00, UL Indoor Open Type
Operating temperature -10° C to 60° C, above 40° C with derating
Storage temperature – 25° C to + 60° C
Operating Altitude 0 – 1000 m, above 1000 m with derating
Humidity 5% to 95% Relative Humidity
Pollution degree Pollution Degree 3
Heat Dissipation
During start 4.5 watts per ampere

Control Panel VLT® LCP 501

  • MCD500-Fact-Sheet_new-8_001A full function HMI interface
  • – everything you can do on the VLT® Soft Starter MCD 500 is possible via the LCP 501
  • Danfoss “FC” menu structure and button interface concept
  • Multiple language selection
  • – incl. Russian and Chinese
  • Full graphics
  • Real language in 4 lines
  • Full parameter list, Quick Menu and application setup
  • Adjustable multiple monitoring views
  • A “copy-paste” function allows the user to copy parameter settings in the LCP and load to other unit.
  • IP 65, NEMA 12
  • 3 m cable and mounting kit included
Dimensions
Current rating [A] Weight [kg] Height [mm] Width [mm] Depth [mm] Frame size
21, 37, 43 and 53 4.2 295 150 183 G1
68 4.5 295 150 183 G1
84, 89 and 105 4.9 295 150 213 G1
131, 141, 195 and 215 14.9 438 275 250 G2
245 23.9 460 390 279 G3
360, 380 and 428 35 689 430 302 G4
595, 619, 790 and 927 45 689 430 302 G4
1200, 1410 and 1600 120 856 585 364 G5